Resolution Test Targets (2024)

TypePhotolithographicBirefringent
Design Chrome-on-GlassBirefringent Pattern
Substrate Clear Soda Lime Glass a Varies b
Chrome Thickness 0.120 µmN/A
Substrate Thickness 0.06" (1.5mm)Varies b
Line Spacing Tolerance c ±1 µmN/A
Line Width Tolerance c ±0.5 µmN/A
  • The positive targets consist of low-reflectivity chrome patterns etched on soda lime glass. The negative targets use the same low-reflectivity chrome coating to cover the substrates, leaving the patterns clear.
  • See the descriptions of each target below for these specifications.
  • This tolerance is valid for the mask used to create these targets and may differ minimally for the targets themselves.

Click to Enlarge
An R2L2S1N NBS 1963A Resolution Target Mounted in an XYF1 Test Target Positioner

Quick Links

  • 1951 USAF Resolution Test Targets, Ø1"
  • 1951 USAF Resolution Test Targets, 1" x 1"
  • 1951 USAF Resolution Test Targets, 1.5" x 1.5"
  • 1951 USAF Resolution Test Targets, 3" x 1"
  • 1951 USAF Birefringent Resolution Test Target, 3" x 1"
  • 1951 USAF Resolution Test Targets, 3" x 3"
  • NBS 1952 Resolution Test Target, 3" x 1"
  • NBS 1952 Resolution Test Target, 3" x 3"
  • NBS 1963A Resolution Test Targets, 2" x 2"
  • High-Frequency NBS 1963A Resolution Test Targets, 2" x 2"
  • NBS 1963A Birefringent Resolution Target, 2" x 2"
  • Sector Star Targets, 1" x 1"
  • Ronchi Ruling Targets, 3" x 1"
  • Variable Line Grating, 3" x 1"
  • Concentric Circles and Crosshairs Grid Target, 3" x 3"
  • Combined Resolution and Distortion Test Targets, 18 mm x 18 mm
  • Combined Resolution and Distortion Test Target, 3" x 1"

Resolution test targets are typically used to measure the resolution of an imaging system. They consist of reference line patterns with well-defined thicknesses and spacings and are designed to be placed in the same plane as the object being imaged. By identifying the largest set of non-distinguishable lines, one determines the resolving power of a given system. Thorlabs offers resolution test targets with 1951 USAF, NBS 1952, and NBS 1963A patterns. Targets are also available with sector star (also known as Siemens star) patterns, Ronchi rulings, a variable line grating, or a combination of patterns for resolution and distortion testing. For more information on each pattern, see the Resolution Targets tab.

All of our resolution test target patterns are available as positive targets, and many have negative versions as well. We also offer several versions of high-contrast positive reflective targets. The positive targets consist of low-reflectivity, vacuum-sputtered chrome patterns plated on clear substrates and are useful for front-lit and general applications. The negative targets use low-reflectivity chrome to cover the substrates, leaving the patterns clear, and work well in back-lit and highly illuminated applications. The positive reflective targets are composed of alow-reflectivity chrome pattern etched on soda lime glass with a chrome background for high contrast in reflective applications. See theGraphs tab for spectral data of the materials used in these test targets. Each pattern is manufactured using photolithography, allowing for edge features to be resolved down to approximately 1 µm.

Mounting
These resolution test targets can be mounted in one of four of our microscopy slide holders. Our MAX3SLH Fixed Slide Holder provides two spring clips to mount the optic and can be mounted to any of our 3-axis translation stages. The MAX3SLH is only compatible with test targets greater than or equal to 2" wide and provides a clear aperture of 1", which may cover the chrome pattern on some of the test targets. Thorlabs also offers our XYF1(/M) Test Target Positioning Mount (see photo to the right) capable of translating a 1" to 3" wide rectangular target over a 50mm x 30mm area. The mount offers five 8-32 (M4) taps for six post-mountable orientations. The XYF1 uses nylon-tipped setscrews to secure the optic. Please note that the mount's support arms overlap the optic by 4.4mm on each side. For users of the MLS203 Microscopy stage we offer the MLS203P2 Slide Holder for Inverted Microscopes, which can mount slides 25mm to 26.5mm wide and petri dishes 30mm to 60mm in diameter.

Photolithographic Target Manufacturing
Our extensive production capabilities enable us to provide solutions for imaging system calibration and measurements. We use contact photolithography with a mask aligner to define the pattern on the glass substrate. Once the pattern is defined, we chemically etch the substrates and clean them in a class 100 cleanroom.

Birefringent Target Manufacturing
OurR3L1S1B and R2L2S1B Birefringent Resolution Targets have a pattern that is invisible unless viewed through a pair of crossed polarizers, making them ideal for calibration of polarization-sensitive systems. The pattern is created by using a photo alignment process to set the fast axis of the liquid crystal polymer layer, which is protected by two layers of glass. These devices are engineered so that the fast axis of the overall target is aligned parallel to the side of the glass covers, whereas the fast axis for the patterned area is aligned 45° to this edge. The entire targets have a retardation of 280 ± 20nm. Additionally, they can display both positive and negative patterns by changing the orientation of the crossed polarizers. If the crossed polarizers are aligned with the sides of the target, the positive image will be formed. If the crossed polarizers are aligned at 45° to the sides of the target, the negative image will be formed.

Thorlabs also offers a complete line of reticles for superimposing a reference pattern onto an object.

Targets Selection Guide
Resolution Test TargetsCalibration Targets Distortion Test Targets Slant Edge MTF Target Stage Micrometers

Click to Enlarge
Line pairs help measure how well a camera can distinguish two objects from one another.

Imaging Resolution

The resolution of an imaging system is often specified in line pairs per millimeter (lp/mm), where a line pair is one light line and one dark line. This value represents the smallest distance between two objects that can be registered by the system; a higher value in lp/mm means the distance between each pair of lines is smaller.

The diagram to the right illustrates the resolution limit of a system. The line pair imaged by the camera on the left cannot be resolved; the two lines are registered by adjacent pixels on the camera sensor, causing them to appear as a single object. In contrast, the line pair on the right has a greater spacing, and thus can be resolved by the system.

The sections below describe the line patterns found on the resolution test targets sold on this page.

1951 USAF Targets

  • Conforms to MIL-S-150A Standard
  • Spurious Resolution Minimized by Line Sets of Three
  • Positive and Negative Targets Available
    • 3" x 3" Targets (10 Groups), 3" x 1" Targets (8 Groups), 3" x 1" Wheel Pattern Targets (6 Groups),1.5" x 1.5" Targets (8 Groups),1" x 1" Targets (8 Groups), 18 mm x 18 mm Combined Targets (6 Groups), Ø1" Targets (6 or 8 Groups), and Ø1" Wheel Pattern Targets (6Groups)
  • 3" x 1" Birefringent Target (6 Groups) Available
1951 USAF Target Options
Item ##of GroupsGroupsConfigurationDimensions
R1DS1P6+2 to +7Single SetØ1"
R1DS1N
R1DS1P180 to +7
R1DS1N1
R1DS1P26+2 to +7Wheel
R1DS1N2
R1L1S1P10-2 to +7Combination18 mm x 18 mm
R1L1S1N
R1L1S7P80 to +7Single Set1" x 1"
R1L1S7N
R2L2S4P1.5" x 1.5"
R2L2S4N
R3L1S4P13" x 1"
R3L1S4N1
R3L1S4P6+2 to +7Wheel
R3L1S4N
R3L1S4PR
R3L1S1B0 to +5Single Set
R3L3S1P10-2 to +7Single Set3" x 3"
R3L3S1N
R3L3S1PR

Resolution Test Targets (3)
Example Line Sets

These resolution targets have a series of horizontal and vertical lines that are used to determine the resolution of an imaging system. A set of six elements (horizontal and vertical line pairs) are in one group, and ten groups compose the resolution chart. The image below shows Elements 2 and 3 of Group -2 on a resolution target.

With line sets of three, these targets offer the advantage of an increased ability to recognize spurious resolution. Spurious resolution occurs when a set of lines is sufficiently blurred such that the overlap appears to form inverted, more distinct lines. This can cause a misreading of the resolution of the optical system, since it will appear that the lines are distinguishable. Spurious resolution also results in the appearance of one less line than exists in the line set. Since the difference between three lines and two is more easily noticed than the difference between five lines and four, for example, it is easier to recognize the occurrence of spurious resolution in targets with sets of only three lines.

Resolution Test Targets (4)

The spacing between the lines in each element is equal to the thickness of the line itself. When the target is imaged, the resolution of an imaging system can be determined by viewing the clarity of the horizontal and vertical lines. The largest set of non-distinguishable horizontal and vertical lines determines the resolving power of the imaging system. The chart below lists the number of line pairs per millimeter for a given element within a group based on the equation below. With our resolution targets, the maximum resolution is 228.0 line pairs per millimeter, which equates to roughly 4.4 µm per line pair. The 3" x 3" targets feature ten groups from -2 to +7; the 3" x 1" targets feature eight groups from 0 to +7; the 3" x 1" wheel pattern versions feature nine targets, each with six groups from +2 to +7; the 3" x 1" birefringent target features six group, from 0 to +5; the 1.5" x 1.5" targets featureeight groups from 0 to +7;the 1" x 1" targets feature eight groups from 0 to +7; the 18 mm x 18mm (0.71" x 0.71") combined targets feature six groups from +2 to +7; the Ø1" targets feature either six groups, from +2 to +7, or eight groups, from 0 to +7; and the Ø1" wheel pattern versions feature six targets, each with six groups from +2 to +7.

ElementGroup Number
-2-101234567
10.2500.5001.002.004.008.0016.0032.0064.00128.00
20.2800.5611.122.244.498.9817.9536.071.8144.0
30.3150.6301.262.525.0410.1020.1640.380.6161.0
40.3530.7071.412.835.6611.3022.6245.390.5181.0
50.3970.7931.593.176.3512.7025.3950.8102.0203.0
60.4450.8911.783.567.1314.3028.5057.0114.0228.0

Values are in lp/mm.

Click to Enlarge
Close Up of the R3L3S6P NBS 1952 Target

NBS 1952 Targets

  • Allows for One-Pass Scanning
  • Spurious Resolution Minimized by Line Sets of Three
  • Positive Targets Available
  • 1" x 3" and 3" x 3" Sizes

NBS 1952 Targets have sets of three vertical lines and sets of three horizontal lines. Each line and the space between it and the next line can be thought of as a line pair or a cycle. The resolution that each target is able to test is given by the frequency of line pairs in line pairs/mm (lp/mm). A list of every frequency available between our two NBS 1952 targets is given in the table below, along with the corresponding line widths.

These targets offer two main advantages: the minimization of spurious resolution and the feasibility of one-pass scanning. Spurious resolution occurs when a set of lines is sufficiently blurred such that the overlap appears to form inverted, more distinct lines. This can cause a misreading of the resolution of the optical system, since it will appear that the lines are distinguishable. Spurious resolution also results in the appearance of one less line than exists in the line set. Since the difference between three lines and two is more easily noticed than the difference between five lines and four, for example, it is easier to recognize the occurrence of spurious resolution in targets with sets of only three lines.

The advantage of one-pass scanning is made possible by the arrangement of the line sets on these targets. The horizontal and vertical line sets are arranged in an identical fashion, with identical frequencies, such that the target is symmetric across a diagonal line from the upper left to the lower right. If one scans from left to right or from top to bottom on the target, the frequency of the lines will increase until the center is reached and then decrease to the opposite edge. Whether done horizontally or vertically, this single pass across the full pattern covers each frequency available on the target. Thus, movement in only one direction is required to determine the resolution of an optical system.

Resolution (lp/mm)Line Width (µm)Resolution (lp/mm)Line Width (µm)Resolution (lp/mm)Line Width (µm)Resolution (lp/mm)Line Width (µm)
0.481041.72.24223.26.873.52025
0.56892.92.4208.3862.52420.8
0.68735.32.72183.39.652.12817.9
0.86252.8176.811.244.63414.7
0.96520.83.2156.31241.74012.5
1.12446.43.4147.113.636.84810.4
1.36367.641251435.7568.9
1.6312.54.8104.21631.3687.4
1.92260.45.689.31729.4806.3

Click for Details
Microscope Image of R2L2S1N Negative Test Target

NBS 1963A Targets

  • Positive, Negative, and Birefringent Targets Available
  • High-Frequency Option
  • 2" x 2" Size for Dedicated Targets, 1" x 3" Size for Combined Target

NBS 1963A Targets have line sets of five vertical and five horizontal lines. Each line and the space between it and the next line can be thought of as a line pair or a cycle. The resolution that each target is able to test is given by the frequency of the cycles in cycles/mm. On Thorlabs' NBS 1963A targets, each line set is labeled with its frequency. By determining the smallest lines that are distinguishable (highest cycles/mm), you can determine the resolution of an imaging system.

Our standard NBS 1963A targets offer 26 line sets with resolutions scaled from 1.0 cycles/mm to 18.0 cycles/mm. For more rigorous resolution testing, our high-frequency NBS 1963A targets have 48 line sets with frequencies from 1.0 cycles/mm to 228 cycles/mm, and our R1L3S5P combined resolution and distortion test target has 35 line sets with frequencies from 4.5 cycles/mm to 228 cycles/mm. The size of each cycle is simply the reciprocal of the frequency and is given for all available frequencies in the table below. For the individual line width, divide the cycle size in half.

Cycles/mmCycle SizeCycles/mmCycle SizeCycles/mmCycle SizeCycles/mmCycle Size
1.01.00 mm4.00.250 mm16.00.063 mm64.00.016 mm
1.10.909 mm4.50.222 mm18.00.056 mm72.00.014 mm
1.250.800 mm5.00.200 mm20.00.05 mm81.00.012 mm
1.40.714 mm5.60.179 mm23.00.043 mm91.00.011 mm
1.60.625 mm6.30.159 mm25.00.040 mm1020.010 mm
1.80.556 mm7.10.141 mm29.00.034 mm1140.009 mm
2.00.500 mm8.00.125 mm32.00.031 mm1280.008 mm
2.20.455 mm9.00.111 mm36.00.028 mm1440.007 mm
2.50.400 mm10.00.100 mm40.00.025 mm1610.0062 mm
2.80.357 mm11.00.091 mm45.00.022 mm1810.0055 mm
3.20.313 mm12.50.080 mm51.00.020 mm2030.0049 mm
3.60.278 mm14.00.071 mm57.00.018 mm2280.0044 mm

Click to Enlarge
Close Up of the R1L1S3P Sector Star Pattern

Sector Star Targets

Sector star targets, also known as Siemens star targets, consist of a number of dark bars that increase in thickness as they radiate out from a shared center. The blank spaces between the bars can themselves be thought of as light bars, and they are designed to be the same thickness as the dark bars at any given radial distance. Theoretically, the bars meet only at the exact middle point of the target. Some sector star targets, including all those sold on this page, have a blank center circle that cuts the bars off before they touch. However, depending on the resolution of the optical system through which the targets are viewed, the bars will appear to touch at some distance from the center. By measuring this distance, the user is able to define the resolution of the optical system.

To calculate the resolution at any given radial distance from the center of the sector star, start by calculating the thickness of a line pair, or one dark bar and one light bar, at that radius. This can be done using the formula for the chord length, given below, where r is the radial distance from the center. The angle Θ is the number of degrees covered by one pair of light and dark bars and is equal to 360° divided by the total number of bars. Once the thickness of the line pair is calculated, the resolution is the reciprocal of the thickness.

Resolution Test Targets (8)Resolution Test Targets (9)

Thorlabs offers two dedicated sector star targets (R1L1S2P and R1L1S3P) and three targets that include sector stars along with other patterns (R1L3S5P, R1L1S1P, and R1L1S1N). The table below summarizes the sector star pattern on each target.

Item #Pattern TypeSector Star Pattern Outer DiameterCenter Circle DiameterNumber of BarsResolution at Outer DiameterResolution at Center Circle
R1L1S2PPositive10 mm200µm36 Over 360°1.15 lp/mm57.5 lp/mm
R1L1S3P72 Over 360°2.29 lp/mm115 lp/mm
R1L3S5PPositive2 mm100µm36 Over 360°5.75 lp/mm115 lp/mm
R1L1S1PPositive2 mm20µm36 Over 360°5.75 lp/mm575 lp/mm
R1L1S1NNegative

Click to Enlarge
Close Up of R1L3S14N Ronchi Ruling Pattern

Ronchi Rulings

Ronchi ruling targets are optical targets consisting of square wave, constant-interval bars as seen in the image to the right. The design produces a precise, large-area, single-frequency pattern and is excellent for evaluating resolution, field distortion, and parfocal stability in optical systems. The grating resolution is defined by the number of line pairs in a given amount of space and is given in line pairs per millimeter (lp/mm).

Thorlabs offers Ronchi ruling targets with a range of resolutions from 10 lp/mm to 80 lp/mm. The table below gives the included pattern resolution and aperture of each target.

Item #ResolutionClear Aperture
R1L3S12N10 lp/mm65 mm x 17 mm
R1L3S13N20 lp/mm
R1L3S14N40 lp/mm
R1L3S15N80 lp/mm

Click to Enlarge
Close Up of R1L3S6P Variable Line Grating Pattern

Variable Line Gratings

Line gratings consist of dark, parallel bars with widths that are equal to the distance between them. In any line grating, one dark bar and one blank space compose a line pair. The resolution of an optical system is dependent on its ability to distinguish adjacent line pairs. Thus, the grating resolution is defined by the number of line pairs in a given amount of space and is typically given in line pairs per millimeter (lp/mm). A variable line grating has some number of grating sections, which increase or decrease in resolution as you move from one to the next. By identifying the highest resolution line grating that an optical system is able to resolve, the user determines the resolution of the system.

Thorlabs offers a variable line grating target with a range of resolutions from 1.25 lp/mm to 250 lp/mm. The table below gives the included resolutions along with a conversion of the line pair size.

lp/mmLine Pair Sizelp/mmLine Pair Sizelp/mmLine Pair Size
1.250.80 mm3.850.26 mm16.670.06 mm
1.670.60 mm4.170.24 mm500.02 mm
2.080.48 mm5.00.20 mm1000.01 mm
2.50.40 mm6.670.15 mm2000.005 mm
2.860.35 mm10.00.10 mm2500.004 mm
3.330.30 mm12.50.08 mm--

Click to Enlarge
This graph shows the transmission of the soda lime glass used in the positive and negative test targets. It is not representative of the soda lime glass used in the R3L1S1B birefringent 1951 USAF test target.

Click to Enlarge
Spectral Curves of Reflective Test Targets
The large difference between the chrome (blue line) and low-reflectivity coatedchrome (red line) in the visible region means that the positive reflective targets have high contrast between the pattern and the background.

Click to Enlarge
This graph shows a sampletransmission curve of aR3L1S1B birefringent target, including the slide, cover glass, and birefringent liquid crystal polymer layer.

Click to Enlarge
This graph shows the transmission of a 10 mm thick sample of N-BK7, the material used for the substrate and cover plate of the R2L2S1B birefingent target.

Resolution Test Targets (16)
Jason Williamson
General Manager
Thorlabs Spectral Works

Questions?
Need a Quote?

Customization Parameters
Substrate SizeaMin8 mm x 8 mm (5/16" x 5/16")
Max85 mm x 85 mm (3.35" x 3.35")
Substrate MaterialsSoda Lime Glass
UV Fused Silica
Quartz
Coating MaterialChromeb
Low-Reflectivity Chromec
Coating Optical Density≥3d or ≥6e @ 430 nm
Minimum Pinhole/SpotØ1 µm
Minimum Line Width1 µm
Line Width Tolerance-0.25 / +0.50 µm
Maximum Line Density500 lp/mm
  • Substrates can be diced to custom shapes and sizes.
  • Chrome Reflectance >40% at 430 nm
  • Low-Reflectivity Chrome Reflectance >10% at 430 nm
  • Optical densities of ≥3 at 430 nm for UV fused silicasubstrates and standard soda lime substrates.
  • Optical density of ≥6 at 430 nm for quartz substrates and select soda lime substrates.

Custom OEM Test Targets and Reticles

Our in-house photolithographic design and production capabilities enable us to create a range of patterned optics. We manufacture test targets, distortion grids, and reticles at our Thorlabs Spectral Works facility in Columbia, South Carolina. These components have served a wide variety of applications, being implemented in microscopes, imaging systems, and optical alignment setups.

In addition to our catalog test targets and reticles offered from stock, we can provide custom chrome patterns on soda lime, UV fused silica, or quartz substrates from 8 mm by 8 mm up to 85 mm by 85 mm. Substrates can be cut to shape for your application. Our photolithographic coating process allows us to create chrome features down to 1 µm. A few sample patterns are shown below, which can be made positive or negative, as shown in the image directly below.

For a quote on custom test targets and reticles, please contact us at TSW@thorlabs.com.

Sample Patterns

Click to Enlarge

Click to Enlarge

Click to Enlarge

Click to Enlarge

Click to Enlarge

Click to Enlarge

Click to Enlarge

Click to Enlarge

Example Applications

  • Etched Reticles
  • Gray Scale Masks
  • Resolution Reticles
  • Diagnostic Reticles
  • Recreational Scopes
  • Notching Reticles
  • Eyepiece Scales
  • Illuminated Crosshairs
  • Obstruction Targets
  • Binocular Reticles

Click to Enlarge
Positive and Negative Crosshair Sample Pattern

This tab details an optimal cleaning technique developed by our engineers for cleaning reticles, test targets, distortion targets, and calibration targets.

Cleaning Procedure

  1. Use a clean wet sponge, preferably made of polyvinyl alcohol (PVA), and dish detergent to gently scrub the front and back surfaces of your reticle or target.
  2. Rinse with water.
  3. Blow dry with clean dry air, or allow the reticle or target to air dryon a clean surface.

We do not suggest using a towel, rag, or wipe to dry the surface. If contamination persists, soak the reticle or target in a detergent and water solution for 1 hour, repeating as necessary.


Posted Comments:

Minh-Chau Nguyen &nbsp(posted 2024-06-14 09:11:59.607)

Hello,My name is Minh-Chau Nguyen, R&D engineer at Phasics SA, France. I am writing you in order to consult the characteristics of the birefringent test target R3L1S1B.I carried out a measurement of the retardance on your test target. The measurement is based on the light intensity while rotating a linear retarder under a polarized incident beam. The retardance is then calculated from the min and max of intensity. From the result, I have some conclusions:- A significant retardance presents on the whole test target (inside and outside the pattern).- The measured retardance is close to the data announced by Thorlabs. The difference of retardance is relatively small between the pattern and the surrounding zone. - The difference between the pattern and the surrounding zone is mostly on the angle of fast-axis (Δθ ≈ 33°), which is not mentioned in the description.Can you please validate my method of measurement as well as the result on the retardance and the angle of fast-axis, since it is not clearly mentioned in the description?I am looking forward to hearing from you soon. Thank in advance.Yours sincerely,Minh-Chau Nguyen

Yudong Fan &nbsp(posted 2024-05-21 21:03:23.003)

The .step file and solidwork file are not valid

cdolbashian &nbsp(posted 2024-05-24 02:45:45.0)

Thank you for reaching out to us. I have contacted you directly to inquire regarding the problems you are having with the step files.

Michael Tan &nbsp(posted 2024-04-16 15:05:28.9)

Hi, I would like to check if there is the same negative target but with smaller diameter available for purchase?

ksosnowski &nbsp(posted 2024-04-22 04:20:33.0)

Hello Michael, thanks for reaching out to Thorlabs. We have offered some custom patterns and sizes before. I have reached out directly to discuss your application in further detail.

luo kun &nbsp(posted 2023-12-04 16:23:03.573)

group 2-7中1-6分别对应多少lp/mm

cdolbashian &nbsp(posted 2023-12-11 10:44:00.0)

Thank you for reaching out to us with this inquiry. All information regarding the line spacing and frequency is outlined on the product page above. Additionally, as this is an industry standard test target pattern, 1951 USAF test target, additional information can be found on the web. I have linked you to some of these resources via email.

Louise Baehr &nbsp(posted 2022-10-26 11:59:29.04)

Dear Sir or Madam,I am sorry to bother you. I would like to have more information on how you calculated the outer and inner frequency of your Siemens star target. Indeed, when I use your formula, taking 72 bars and so theta = 360°/72 = 5 and the outer diameter of 10mm, I get:c = 2 * 10mm * sin(5°/2) = 0.8724 mmresolution = 1 / 0.8724 = 1.1463 lp/mm BUT, in your table, you indicate a frequency of 2.29 lp/mm at the outer diameter. Could it be possible to have the details of your calculations ? It seems I'm missing something and I really need to understand.Thank you very much and sorry again for bothering you.Best regards

cdolbashian &nbsp(posted 2022-10-31 01:52:36.0)

Thank you for reaching out to us! I think perhaps you may be overlooking the negative space between each feature. The size of each line pair should be considered in the 72 segments. Simply take the number of line pairs (72) and divide by the circumference of the circle (2*Pi*5mm~31mm). Taking this quotient (72/31mm) yields ~2.29lp/mm. I have contacted you directly to address this further.

Kimi Huang &nbsp(posted 2022-02-17 16:32:57.09)

Hi Sir,A question about Reflectivity of pattern and clear area.Would like to check the Reflectivity % of pattern is ? in the plot, it looks have high R% of pattern? but not make sense to me becuase pattern is black pattern. So I think I misunderstand something here.So, the question is : what is the Reflectivity of Pattern and clear I should use in the model?Thanks

cdolbashian &nbsp(posted 2022-02-18 05:09:16.0)

Thank you for reaching out to us Kimi. The substrate of the R1DS1P is soda lime glass, while the pattern is made with anti-reflective chrome. The reflectivity of the chrome and the transmission of the soda lime, can be found on the "Graphs" tab on this page. You can approximate the reflectivity of the soda lime glass as 1-Transmission at a given wavelength, but for a true reflectivity value, one must also consider the absorption of the soda lime substrate. I have reached out to you directly to discuss this further in context of your particular light source.

Ulrich Leischner &nbsp(posted 2021-11-03 07:47:52.73)

I need the precise values of the lines in this target. the value LP/mm is not completely clear. Is this the full diameter of 3 lines, or is this the periodic length (full diameter of 2 lines, a negative and a positive one)A drawing with the values in the PDF would be very helpful.Regards

jgreschler &nbsp(posted 2021-11-12 04:45:20.0)

Thank you for reaching out to Thorlabs. The definition of line pairs per millimeter (lp/mm) is defined by a pair of lines, one bright and one dark, in a given spacing. For example, if the specification is 1 lp/mm, that means that the coated line is 0.5mm and the uncoated line is 0.5mm. You can read more about this definition in our Resolution Targets tab at the top of the product page, further literature can be found here https://en.wikipedia.org/wiki/1951_USAF_resolution_test_chart

Fidel Vega &nbsp(posted 2021-10-11 04:24:48.963)

Dear Sir or Madam,We are interested in buying some customized reticles & calibration tests. I would need to contact your technical department to ask some questions about the features of the items that we need. The 1st October I sent a message to TSW@thorlabs.com with this request, but I have not yet received any feedback from your side.Thank youFidel

cdolbashian &nbsp(posted 2021-12-23 11:38:58.0)

Thank you for contacting us here at Thorlabs! We apologize deeply for our lack of communication. We have reached out to you directly to discuss your custom.

Andrew Keys &nbsp(posted 2021-08-19 12:14:32.71)

I recently ordered a positive and negative version of the R1L1S1P Resolution and Distortion Target. To be able to precisely navigate around the elements on this target, I ordered a XYF1 mount. Upon receipt, I now realize that the 18mm x 18mm target cannot easily be mounted in the XYF1 without covering much of the target elements. What is the recommended method of mounting these R1L1S1P targets?

cdolbashian &nbsp(posted 2021-08-27 09:29:10.0)

Thank you for reaching out to us here at Thorlabs! The test target you have selected is intended for use with a standard microscopy system, rather than free space optics. Because this is the case, using it with the XYF1 may result in the obscuration of some of the edges of the test pattern, due to the size of the target. I have reached out to you directly with alternative solutions. We are always hungry for feedback, so we appreciate you bringing this incompatibility of seemingly-compatible parts to our attention.

moti yanuka &nbsp(posted 2021-02-17 20:19:35.317)

I am interested in resolution and distortion targets, could you send to me quotations?

YLohia &nbsp(posted 2021-02-17 10:20:33.0)

Hello, thank you for your interest in our products. Quotes can be requested by contacting our Sales Team (sales@thorlabs.com) or by adding the items to your cart and clicking "Request a Quote" button on your cart page.

Ananth Rao &nbsp(posted 2020-09-15 06:34:45.553)

Hi ,We have bought this resolution target R1L1S1N, there are two peculiar questions,1. What is methodology to clean the target? Is there any documentation?2. What is the surface flatness of the target?

YLohia &nbsp(posted 2020-09-16 10:32:26.0)

Hello, thank you for contacting Thorlabs. Unfortunately, we don't have specific documentation on cleaning the R1L1S1N. That being said, we do have a general optics cleaning guide here: https://www.thorlabs.com/newgrouppage9.cfm?objectgroup_id=9025. I have reached out to you directly to discuss your request.

wen cao &nbsp(posted 2020-06-24 09:12:46.36)

这个分辨率板是透明的吗?可以背光照射吗?

YLohia &nbsp(posted 2020-06-24 09:15:24.0)

Thank you for contacting Thorlabs. An applications engineer from our team in China (techsupport-cn@thorlabs.com) will reach out to you directly.

程访 许 &nbsp(posted 2019-11-26 16:41:58.167)

此产品镀的铬膜,对633nm的光,反射率是多少?望回复,我在产品介绍中没看到,最近课题组购买了此产品,我需要这个参数。

nbayconich &nbsp(posted 2019-12-03 04:04:53.0)

Thank you for contacting Thorlabs. Although we do not specify a guaranteed reflectivity of this chrome coating, the reflectivity will be about 25% at 633nm. I will reach out to you directly.

Soocheol Kim &nbsp(posted 2019-11-19 21:33:39.29)

Dear Sir/Madame, I checked the retardation of the entire target, which was to be 280±20 nm.Is this retardation a retardation between the entire target and the patterned area?I'd like to know the retardation between the entire target and the patterned area.

nbayconich &nbsp(posted 2019-11-25 10:35:23.0)

Thank you for contacting Thorlabs. The R2L2S1B is a half wave plate for 546 nm (or 273nm @546nm). The entire target has the same retardance, the pattern is created by having a 45 deg azimuth difference against the background.

Anne De Paepe &nbsp(posted 2019-11-06 10:27:10.69)

Dear Sir/Madam,I am looking for a spatial resolution test for my Raman microscope (532nm, 633nm and 785nm lasers). Where I worked before we had a USAF target of Si on Quartz but not sure if this is the best one. What would you recommend?Thank you

YLohia &nbsp(posted 2019-11-08 10:51:17.0)

Hello, thank you for contacting Thorlabs. Our Chrome on Glass targets are suitable for all wavelengths mentioned by you. Ultimately, the use comes down to personal preference, availability, and possible requirements on transmission/reflectivity. I have reached out to you directly to gain a better sense of your needs.

Soojung Kim &nbsp(posted 2019-11-05 08:24:52.273)

Hello.How thick is the patterned chrome on R1L1S1P test target? It's very important point to test axial resolution of our equipment.Sincerely.

YLohia &nbsp(posted 2019-11-05 10:46:52.0)

The thickness of the chrome layer on our targets is 0.120 µm. More information can be found in the specs table in the Overview tab.

Fernando Brandi &nbsp(posted 2019-08-13 08:52:46.3)

Dear Sir/Madame,I am interested in you R2L2S1BBirefringent NBS 1963A Resolution Target, 2" x 2" for testing a polarizing imaging system.For our porpoises we need to use both fundamental 1064 nm and second harmonic 532 nm laser light.In order to evaluate the use of the R2L2S1BBirefringent NBS 1963A Resolution Target for our application I need to know the total optical path length of the target at the two wavelength (1064 nm and 532 nm) and for both ordinary and extraordinary polarization orientation.Looking forwrd for your reply I thank you for the attention.Kind regards,Fernando Brandi, PhDConsiglio Nazionale delle Ricerche (CNR)Istituto Nazionale di Ottica (INO)Sede Secondaria "A. Gozzini" di PisaVia Moruzzi 1, 56124-Pisa, ItalyTel. +39 050 315 2584Fax. +39 050 315 2247E-Mail: fernando.brandi@ino.cnr.ithttp://research.ino.it/Groups/ilil/it/about_it/

YLohia &nbsp(posted 2019-08-28 03:45:30.0)

Hello Fernando, thank you for contacting Thorlabs. The design wavelength for half-wave retardance for the R2L2S1B is 546nm. The liquid crystal delta(n) is 0.1555 at 550 nm. Unfortunately, we do not have the data for your exact operating wavelengths. We reached out to you directly to discuss this further.

user&nbsp(posted 2019-07-01 11:43:13.403)

What mechanical mount do you suggest to hold R1L1S1P or R1L1S1N?

YLohia &nbsp(posted 2019-07-01 12:19:11.0)

Hello, thank you for contacting Thorlabs. We recommend the XF50, PC2, FH2, SFH2, CH1A, or FP01 mounts for these targets.

Robert Standaert &nbsp(posted 2019-05-13 16:45:12.813)

High-resolution or vector images of the targets would be very helpful.

YLohia &nbsp(posted 2019-05-14 10:10:55.0)

Hello, thank you for your feedback! We are in the process of discussing the possibility of publishing this information on our website.

sureshbil67 &nbsp(posted 2018-08-11 07:29:46.71)

I want to know resolution target patterns specification of Night vision devices

YLohia &nbsp(posted 2018-09-17 09:59:01.0)

Hello, thank you for contacting Thorlabs. I have reached out to you directly to discuss your application in more detail.

haolin.zhang &nbsp(posted 2018-05-09 20:12:29.3)

I am using the R2L2S1B Resolution Target to implement a holographic experiment. Could you please provide me the refractive index of the liquid crystal polymer layer aligned in the target, please? Also, could you please provide the information about the material of this liquid crystal polymer layer? Thanks in advance.

YLohia &nbsp(posted 2018-05-11 08:39:33.0)

Hello, thank you for contacting Thorlabs. Unfortunately, we cannot disclose this information since it is proprietary.

ayoub.mghari &nbsp(posted 2017-11-29 11:27:24.9)

I am interested in ordering this target but I have the following question:My understanding is that the target is made out of Chrome coating on Soda Lime Glass. This, due to a given illumination system will result in shadows on the rear side, correct? Is it possible to have this target on a non-transparent glass? Please send me a Quote by E-mail.

nbayconich &nbsp(posted 2017-12-27 04:07:26.0)

Thank you for contacting Thorlabs. You are correct if using the positive resolution targets then light incident on the front of the target light will reflect off of the chrome patterns. The negative targets have clear patterns with chrome coating the rest of the substrate which makes these intended for back lit applications. We can provide custom targets with non-transparent substrate such as opal. I will reach out to you directly to discuss our custom target capabilities.

miguel.pleitez &nbsp(posted 2017-05-24 13:59:18.767)

would it be possible to get this test targets but on a ZnSe substrate instead of glass? I would be very interested on them. Let me know.Thanks in advance.

nbayconich &nbsp(posted 2017-06-13 09:48:26.0)

Thank you for contacting Thorlabs. I will contact you directly about our custom capabilities.

yoonys &nbsp(posted 2016-12-06 01:07:03.37)

It'd be helpful to draw what "line pair" is on the website, like Figure 1(b) in the following link.http://www.edmundoptics.com/resources/application-notes/imaging/resolution/

tcampbell &nbsp(posted 2016-12-15 11:47:36.0)

Response from Tim at Thorlabs: Thank you for your feedback. We will look into adding a diagram explaining line pairs and camera resolution soon.

theodore_morse &nbsp(posted 2016-11-16 11:49:07.157)

I wish to use a blue laser (266 nm) to get the resolution. In the masks that you use, will it transmit blue light? I would prefer it to be a quartz substrate.Ted MorseProf. (Research)School of EngineeringBrown UniversityProvidence, RI 02912

tfrisch &nbsp(posted 2016-11-18 10:32:42.0)

Hello Ted, thank you for contacting Thorlabs. I am checking on the transmission and reflection of the chrome and soda lime in UV regions now. I will contact you directly when I have more information.

user&nbsp(posted 2014-06-02 12:59:19.84)

What is the line width of the grids on the R1L1S1P resolution target?

jlow &nbsp(posted 2014-06-03 10:41:23.0)

Response from Jeremy at Thorlabs: The grid line width is 5µm for both the 100µm and 50µm grids, and 1.5µm for the 10µm grid.

pnon &nbsp(posted 2012-12-24 11:58:00.0)

Response from Pauline at Thorlabs: The masks used for our test targets are calibrated to NIST-traceable standards. We use contact photolithography with a mask aligner to define the pattern on the glass substrate. Once the pattern is defined, we chemically etch the substrates to produce the finished targets. Although similar in performance with the mask, we do not provide NIST traceable certificates. I will contact you shortly to provide information in getting targets with NIST certificates.

mmarcoux &nbsp(posted 2012-12-17 10:05:40.897)

Are the R1L3S3P distortion targets N.I.S.T. certified/traceable?

tcohen &nbsp(posted 2012-06-18 10:51:00.0)

Response from Tim at Thorlabs: Information on this question was provided for a previous request @400nm below: “The reflectivity of dark pattern on reticle is less than 12% @400nm. For the white pattern, it is just sodium lime glass, so the reflectivity is estimated to be ~ 3.5% @ 400nm ( assuming refractive index is ~ 1.463).” I have contacted you to find out your wavelength and to see if you require more information.

cooljkpark &nbsp(posted 2012-06-15 07:09:36.0)

Can you tell me the reflection coefficient of glass and chrome in your resolution target?

bdada &nbsp(posted 2012-06-05 19:09:00.0)

Response from Buki at Thorlabs to marctessier:Thank you for participating in our feedback forum. We are developing some new crossed reticles and we have contacted you for a drawing of the custom reticle you need. We have an office in France and the information is included on the web page linked below that lists our offices and distributors world wide:http://www.thorlabs.de/Distributors.cfm

marctessier &nbsp(posted 2012-06-05 17:31:41.0)

Hello,I'm working in Rillieux la Pape, near Lyon, in France, and I must find a custom 1" crossed reticle. I've a PDF file showing it.I need only one part.Are you able to supply such good?Do you have a french retailer?Best regards,Marc

bdada &nbsp(posted 2012-02-27 17:34:00.0)

Response from Buki to dick.verhaart:For our reticle products, we use chrome with O.D.=>3.0 @430nm. The reflectivity of dark pattern on reticle is less than 12% @400nm. For the white pattern, it is just sodium lime glass, so the reflectivity is estimated to be ~ 3.5% @ 400nm ( assuming refractive index is ~ 1.463).Please contact TechSupport@thorlabs.com if you have any questions.

bdada &nbsp(posted 2012-02-24 18:46:00.0)

Response from Buki at Thorlabs to dick.verhaart:Thank you for your feedback. We are looking into this and will contact you shortly with more information and post an update here.

dick.verhaart &nbsp(posted 2012-02-02 05:48:19.0)

Can this product (R3L3S1P/N) be used with 405 nm reflective illumination? I find with similar products from other suppliers that the reflection contrast, at this wavelength, between glass and chrome is very small, contrast reversal may occur. Does Thorlabs specific refelctivity of "black"and "white"at 405 nm?

bdada &nbsp(posted 2011-08-01 14:14:00.0)

Response from Buki at Thorlabs:We measured the smallest grid pattern (10um) of R1L2S2P using a micrometric system, OLYMPUS MX50, and the tolerance of the pattern is < +/-0.1um. Please contact TechSupport@thorlabs.com with additional questions.

ajh &nbsp(posted 2011-07-26 03:05:25.0)

Can you provide specifications for the accuracy of the graduations on your stage micrometers, R1L2S2P and R1L2S1P? I assume they are very accurate but when calibrating image scale you do want to know how accurate your calibrator is.

user&nbsp(posted 2011-01-31 10:50:15.0)

Response from Buki to Paul. Thank you so much for your feedback. We are expanding our selection of reticles and will make them more compatible with our cage system. We will contact you directly to learn how we can better meet your needs.

paul &nbsp(posted 2011-01-24 12:02:31.0)

I am surprised (given the sophistication of your product line)you do not stock reticles that can be used with the cage plate systems. I currently buy reticles elsewhere and then mount them in cage plates.

Resolution Test Targets (2024)
Top Articles
Latest Posts
Article information

Author: Nathanael Baumbach

Last Updated:

Views: 5975

Rating: 4.4 / 5 (55 voted)

Reviews: 86% of readers found this page helpful

Author information

Name: Nathanael Baumbach

Birthday: 1998-12-02

Address: Apt. 829 751 Glover View, West Orlando, IN 22436

Phone: +901025288581

Job: Internal IT Coordinator

Hobby: Gunsmithing, Motor sports, Flying, Skiing, Hooping, Lego building, Ice skating

Introduction: My name is Nathanael Baumbach, I am a fantastic, nice, victorious, brave, healthy, cute, glorious person who loves writing and wants to share my knowledge and understanding with you.